GUGLER Water Turbines
Smart solutions for pumped storage plants
For pumped storage plants up to 20 MW per unit, we offer the perfect solution for every application.
Water storage reservoirs are an efficient battery for storing excess electricity from wind and solar power generation systems.
Hybrid grids are defined by a combination of two or more power generation technologies from renewable energy sources and an energy storage system. We offer solutions for storing energy from renewable sources in “water batteries”, which are filled by pump turbines or pumps and are used via hydro turbines. On the one hand, such systems ensure a power supply when wind or photovoltaic systems are not producing electricity and, on the other hand, help to balance grid loads.
Based on the specific site requirements, we help you choose the best solution for the specific application with:
Fixed or variable speed reversible pump-turbines
Cost efficient machinery – machine unit consisting only of pump turbine and motor/generator
Long service life compared to electrochemical storage solutions
Combinations of pumps and turbines
For applications that require high operational flexibility
Please contact our sales team for advice on the most suitable system for your needs!
You might also be interested in these Projects:
Nam Tha 4, Vietnam, 2020
Scope of Supply: Francis Turbine, Generator, HPU, Inlet valve
Number of Units
2
Total Output (kW)
17 468
Head of water (m)
194,0
Flow (m3/s)
4,9
Runner Diameter (mm)
725
Tanjung Tirta, Indonesia, 2019
Scope of Supply: Francis Turbine, Butterfly Valve, HPU, Generator, Control & Protection Systems, SCADA
Number of Units
2
Total Output (kW)
10 000
Head of water (m)
92,3
Flow (m3/s)
6,0
Runner Diameter (mm)
850
Marañon, Peru, 2015
Scope of Supply: Francis Turbine, Butterfly Valve, HPU, Generator, all Electrical Switchgears, Control & Protection Systems, SCADA, Transformers
Number of Units
3
Total Output (kW)
19 683
Head of water (m)
84,5
Flow (m3/s)
8,7
Runner Diameter (mm)
1 115
Alejandria, Colombia, 2014
Scope of Supply:
Number of Units
2
Total Output (kW)
15 378
Head of water (m)
106,5
Flow (m3/s)
8,0
Runner Diameter (mm)
930
Carpapata III, Peru, 2014
Scope of Supply: Francis Turbine, Generator, Inlet Valve, Hydraulic Power Unit
Number of Units
2
Total Output (kW)
12 874
Head of water (m)
113,8
Flow (m3/s)
6,4
Runner Diameter (mm)
910
Stubenberg, Austria, 2015
Scope of Supply: Francis Turbine, Inlet Valve , Bifurcation, Generator, Hydraulic Power Unit
Number of Units
2
Total Output (kW)
1 698
Head of water (m)
23,4
Flow (m3/s)
4,0
Runner Diameter (mm)
850
GUGLER Water Turbines GmbH Gewerbepark 41, 4101 Feldkirchen an der Donau, Austria +43 7233 20933, info@gugler.com