We supply Kaplan-Turbines up to 20 MW per unit.
The best solution for low pressures with high flow.
Individualised design at state-of-the-art technology provides highest efficiency, longest lifespan and secures extraordinary profitability.
We provide the perfect solution for every application:
Open Flume, Pit, Bulb, Spiral, Siphon Turbines
double or single regulated
horizontal, inclinded or vertical setting
3 to 8 blades
You might also be interested in these Projects:
Sleitustaðavirkjun, Iceland, 2019
Scope of Supply: Kaplan Turbine, Generator, Butterfly Valve, Hydraulic Power Unit, Control- and Protection-System
Number of Units
1
Total Output (kW)
246
Head of water (m)
9,5
Flow (m3/s)
2,8
Runner Diameter (mm)
710
Bodorna, Georgia, 2018
Scope of Supply: Turbine, Generator, Hydraulic Power Unit, Control System, SCADA, Medium Voltage System, Transformer, Diesel Generator
Number of Units
1
Total Output (kW)
2 556
Head of water (m)
8,1
Flow (m3/s)
32,0
Runner Diameter (mm)
2 240
Regio Parco, Italy, 2017
Scope of Supply: Kaplan Turbine, Generator Design, Hydraulic Power Unit
Number of Units
1
Total Output (kW)
454
Head of water (m)
2,4
Flow (m3/s)
21,0
Runner Diameter (mm)
2 300
Poza Verde, Guatemala, 2015
Scope of Supply: Kaplan Spiral Turbine, Generator, HPU, Butterfly Valve, Drainage & Dewatering System, Control & Protection System, Station Service System, SCADA System
Number of Units
1
Total Output (kW)
1 801
Head of water (m)
22,0
Flow (m3/s)
9,0
Runner Diameter (mm)
1 160
Owala, Sri Lanka, 2014
Scope of Supply: Open-Flume Turbine
Number of Units
2
Total Output (kW)
3 400
Head of water (m)
5,9
Flow (m3/s)
28,9
Runner Diameter (mm)
2 550
Strasbourg, France, 2013
Scope of Supply: Kaplan Pit Turbine, Generator, Inletvalve, Hydraulicpowerunit
Number of Units
2
Total Output (kW)
1 144
Head of water (m)
12,1
Flow (m3/s)
6,9
Runner Diameter (mm)
1 030